Written exam
24 questions in 45 minutes, including a survey layout. The passing score is 31 out of 38 points.
Operator training
Plan a metric FF/FL survey, operate the RT Pro profiler and report floor flatness and levelness under ASTM E1155/E1155M.
Course content
Work through five lessons, then demonstrate what you have learned in a written exam and a field assessment.
Open learning workspaceDistinguish flatness from levelness and trace how consecutive profile readings produce Q and Z values. Identify when ASTM F-numbers apply to random-traffic floors.
Divide a floor plan into test sections. Lay out straight runs, allow for exclusions and check that each section provides enough Z values.
Prepare the RT Pro (M), mark the wheel positions and complete calibration. Reverse the instrument on the same marks and use the two readings to decide whether to proceed.
Create a project, surface, section and run. Follow the marked path, check the recorded steps and practice stopping and appending a run.
Export the survey data and produce a report. Compare overall and local results with the project requirements and explain your conclusion.
Assessment
Buildwise awards the RT Pro (M) credential after an assessor confirms that you have passed both parts. You will need access to a metric profiler for the field work.
24 questions in 45 minutes, including a survey layout. The passing score is 31 out of 38 points.
Submit a video of your operating technique, a marked plan, the exported data and a PDF report for review.